SlideShare a Scribd company logo
Antibody Bound Resin
Mycotoxin Affinity Column
Support
Bead
Monoclonal
Antibody
Impurities
Mycotoxins
Vicam Ia Working Principle
Impurities
Mycotoxins bound to
monoclonal antibodies
Column Wash
Mycotoxins bound to
monoclonal antibodies
Methanol elution
Methanol
Mycotoxins
Purified mycotoxins in
methanol
AflaTest
• Limit of detection as low as 0.5 ppb
(fluorometer) 0.05 ppb (HPLC)
• Wide range as high as 320 ppb
• AOAC Official Method status
• USDA-FGIS Certificate of Conformance
FumoniTest
• 0.25 ppm (fluorometer) 0.016 ppm (HPLC)
limit of detection
• Wide range of 0-10 ppm
• Excellent linearity: r = 0.998
• Excellent precision: %CV < 11% from 1-10
ppm
• Fluorometer method correlates well with
HPLC linear regression r = 0.995
• USDA-FGIS Certificate of Conformance
ZearalaTest
• 0.10 ppm (fluorometer) 0.0025 ppm
(HPLC) limit of detection
• Wide range of 0-5 ppm
• Excellent linearity r = 0.999
• Excellent precision: %CV = 13% over the
assay range
• Fluorometer method correlates well with
HPLC linear regression r = 0.990
OchraTest
• Limit of detection as low as 1 ppb
(fluorometer) 0.25 ppb (HPLC)
• Wide range as high as 100 ppb
• Excellent linearity with correlation coefficient
(r) of 0.997-0.999 for wheat, dried fruit and
green coffee
• Excellent precision with %CV <10% at 20
ppb
• Fluorometer method correlates well with
HPLC when analyzed by linear regression
DON FQ

Quick - Results in less than 30 minutes (after
sample extraction.

Sensitive - Detects levels as low as 0.5 ppm

Wide Range - Measures up to 5 ppm

Convenient - Uses same instrumentation as
other VICAM mycotoxin tests

USDA-FGIS Certificate of Conformance
DONtest HPLC
• limit of detection : 0.1 ppm (HPLC)
• Wide range : 0 -10 ppm
• Excellent linearity with correlation coefficient (r)
of 0.999 : r2
= 0.999
• Excellent precision : with %CV 8.3%
• DONtest-HPLC method correlates well with GC-
ECD when analyzed by linear regression: r2
=
0.982
T-2

Quick - Results in less than 20 minutes (after
sample extraction.

Sensitive - Detects levels as low as 0.15 ppm

Wide Range - Measures up to 2.0 ppm

Convenient - Uses same instrumentation as
other VICAM mycotoxin tests

Safe - Requires less toxic materials than other
methods.
T-2 HPLC
• limit of detection : 0.005 ppm
• Wide range : 0 –1.5 ppm
• Excellent linearity with correlation coefficient (r)
of 0.999 : r2
= 0.999
• Excellent precision : RSD 3.68%
Team Medical & Scientific Sdn. Bhd.
41, Jalan Anggerik Vanilla T31/T, Kota Kemuning,
40460 Shah Alam, Selangor
Tel : 603-5122 5108 Fax : 603-5122 1608
Email : info@tms-lab.com Blog : tms-lab.blogspot.com
Solely Distribute by :

More Related Content

PDF
Vicam Ia Working Principle
PPT
Vicam Ia Technology Working Principle
PPTX
11 hptlc jntu pharmacy
PPTX
Performance qualification of High performance liquid chromatography
PDF
Hplc qualification copy
PPTX
High Performance Thin Layer Chromatography
PPTX
Project seminar
PPTX
Calibration and validation of analytical instruments
Vicam Ia Working Principle
Vicam Ia Technology Working Principle
11 hptlc jntu pharmacy
Performance qualification of High performance liquid chromatography
Hplc qualification copy
High Performance Thin Layer Chromatography
Project seminar
Calibration and validation of analytical instruments

What's hot (11)

PPTX
QUALIFICATION OF UV-VISIBLE SPECTROPHOTOMETER, FTIR, DSC, HPLC
PPTX
QUALIFICATION OF HPLC , HPLC
PPTX
High Performance Thin Layer Chromatography(HPTLC)
PPTX
HPTLC method
PPTX
Dhruti Avlani - TLC & HPTLC
PPT
Mitigating acrylamide in potatoe chips interest of fluorescence as monitori...
PPTX
PDF
Qualification of analytical instruments
PDF
MGT-01-Mixed-Gas-Permeability-Analyzer
QUALIFICATION OF UV-VISIBLE SPECTROPHOTOMETER, FTIR, DSC, HPLC
QUALIFICATION OF HPLC , HPLC
High Performance Thin Layer Chromatography(HPTLC)
HPTLC method
Dhruti Avlani - TLC & HPTLC
Mitigating acrylamide in potatoe chips interest of fluorescence as monitori...
Qualification of analytical instruments
MGT-01-Mixed-Gas-Permeability-Analyzer
Ad

Viewers also liked (20)

PPT
Mycotoxin Analysis in your hand – RIDA®SMART APP
PPT
Mycotoxins
PDF
LC-MS/MS: The New Reference Method for Mycotoxin Analysis
PDF
Food Safety - Mycotoxins in Foods
PPTX
Food storage, value addition and mycotoxin management: Research progress from...
PDF
Findings of the report on Mycotoxin Control in Low- and Middle-Income Countries
ODP
Mycotoxins: analysis and human exposure
PPT
Twenty years research on aflatoxin in Europe: what benefits for Africa?
PPTX
Mycotoxin
PPTX
Antimycotoxin_Mycotoxin_Binders
PPTX
Presentation re sakss_ator 2015_aflatoxins-clean
PDF
Kenyan perceptions of aflatoxins: An analysis of raw milk consumption
PPT
MYCOTOXINS and ANIMAL HEALTH: focus on intestinal health
PPTX
Mycotoxins
PPT
MYCOTOXINS IN FEED AND THEIR EFFECTS ON BROILER
PPTX
Mycotoxin
PPTX
Control Of Mycotoxins In Poultry
PPTX
Mycotoxin in poultry feeds ppt
PPTX
Mycotoxins
Mycotoxin Analysis in your hand – RIDA®SMART APP
Mycotoxins
LC-MS/MS: The New Reference Method for Mycotoxin Analysis
Food Safety - Mycotoxins in Foods
Food storage, value addition and mycotoxin management: Research progress from...
Findings of the report on Mycotoxin Control in Low- and Middle-Income Countries
Mycotoxins: analysis and human exposure
Twenty years research on aflatoxin in Europe: what benefits for Africa?
Mycotoxin
Antimycotoxin_Mycotoxin_Binders
Presentation re sakss_ator 2015_aflatoxins-clean
Kenyan perceptions of aflatoxins: An analysis of raw milk consumption
MYCOTOXINS and ANIMAL HEALTH: focus on intestinal health
Mycotoxins
MYCOTOXINS IN FEED AND THEIR EFFECTS ON BROILER
Mycotoxin
Control Of Mycotoxins In Poultry
Mycotoxin in poultry feeds ppt
Mycotoxins
Ad

Similar to Vicam Ia Working Principle (20)

PPTX
Qualification of HPLC & LCMS.pptxfjddjdjdhdjdjj
PPTX
Qualification of HPLC & LCMS.pptdjdjdjdjfjkfx
PPTX
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
PDF
W.A.H.C 2014 The Future of Water Testing is Digital
PPT
Method-Validation-HPLC-case-study
PDF
Pool side testing
PPTX
Presentationastm6591unnikrishnan.pptx
PPTX
PresentationASTM6591[1].pptx
PPT
HPTLC applications and uses in different fields.ppt
PPTX
Food contaminants dhaka university_august2014
PDF
FTIR For Stack and CEM
PPTX
Analytical Method Validation
PDF
Clora-Online
PPTX
Qualification of high performance liquid chromatography
PDF
Pharmaceutical validation
PPTX
validation of analytical method used in cleaning
PPT
Analytical method validation
PPTX
CLEANING VALIDATION for M.pharm and industry person
PPTX
validation and calibration of HPLC
Qualification of HPLC & LCMS.pptxfjddjdjdhdjdjj
Qualification of HPLC & LCMS.pptdjdjdjdjfjkfx
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
W.A.H.C 2014 The Future of Water Testing is Digital
Method-Validation-HPLC-case-study
Pool side testing
Presentationastm6591unnikrishnan.pptx
PresentationASTM6591[1].pptx
HPTLC applications and uses in different fields.ppt
Food contaminants dhaka university_august2014
FTIR For Stack and CEM
Analytical Method Validation
Clora-Online
Qualification of high performance liquid chromatography
Pharmaceutical validation
validation of analytical method used in cleaning
Analytical method validation
CLEANING VALIDATION for M.pharm and industry person
validation and calibration of HPLC

More from Joseph Chan (15)

PDF
Erlab Captair Seminar
PDF
basics of water activity virtual seminar
PDF
Feed webinar _VICAM
PPTX
March 5 Talk
PDF
Vicam Ia Protocol Step By Step
PDF
Vicam Ia Column For Mycotoxins
PPT
Vicam Ia Column For Mycotoxins
PPTX
Series I Workshop : CV Writing
DOC
HPLC Set-Up For Myco6in1
PDF
Q4 LEAP Program 2009
PDF
Q4 GeMMA & FEPAS 2009
PPT
Introduction of PT
PDF
Q4 Fapas Program - Food Chemical
PPT
CV Writing Workshop
PPT
LP 80 Presentation
Erlab Captair Seminar
basics of water activity virtual seminar
Feed webinar _VICAM
March 5 Talk
Vicam Ia Protocol Step By Step
Vicam Ia Column For Mycotoxins
Vicam Ia Column For Mycotoxins
Series I Workshop : CV Writing
HPLC Set-Up For Myco6in1
Q4 LEAP Program 2009
Q4 GeMMA & FEPAS 2009
Introduction of PT
Q4 Fapas Program - Food Chemical
CV Writing Workshop
LP 80 Presentation

Recently uploaded (20)

PDF
LNK 2025 (2).pdf MWEHEHEHEHEHEHEHEHEHEHE
PPTX
Final Presentation General Medicine 03-08-2024.pptx
PPTX
PPT- ENG7_QUARTER1_LESSON1_WEEK1. IMAGERY -DESCRIPTIONS pptx.pptx
PDF
GENETICS IN BIOLOGY IN SECONDARY LEVEL FORM 3
PDF
LDMMIA Reiki Yoga Finals Review Spring Summer
PDF
A systematic review of self-coping strategies used by university students to ...
PPTX
Cell Types and Its function , kingdom of life
PDF
Classroom Observation Tools for Teachers
PPTX
Final Presentation General Medicine 03-08-2024.pptx
PDF
Black Hat USA 2025 - Micro ICS Summit - ICS/OT Threat Landscape
PDF
Supply Chain Operations Speaking Notes -ICLT Program
PDF
Weekly quiz Compilation Jan -July 25.pdf
PPTX
1st Inaugural Professorial Lecture held on 19th February 2020 (Governance and...
PPTX
History, Philosophy and sociology of education (1).pptx
PPTX
Radiologic_Anatomy_of_the_Brachial_plexus [final].pptx
PPTX
Cell Structure & Organelles in detailed.
PDF
Paper A Mock Exam 9_ Attempt review.pdf.
PDF
RTP_AR_KS1_Tutor's Guide_English [FOR REPRODUCTION].pdf
PPTX
UNIT III MENTAL HEALTH NURSING ASSESSMENT
PDF
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf
LNK 2025 (2).pdf MWEHEHEHEHEHEHEHEHEHEHE
Final Presentation General Medicine 03-08-2024.pptx
PPT- ENG7_QUARTER1_LESSON1_WEEK1. IMAGERY -DESCRIPTIONS pptx.pptx
GENETICS IN BIOLOGY IN SECONDARY LEVEL FORM 3
LDMMIA Reiki Yoga Finals Review Spring Summer
A systematic review of self-coping strategies used by university students to ...
Cell Types and Its function , kingdom of life
Classroom Observation Tools for Teachers
Final Presentation General Medicine 03-08-2024.pptx
Black Hat USA 2025 - Micro ICS Summit - ICS/OT Threat Landscape
Supply Chain Operations Speaking Notes -ICLT Program
Weekly quiz Compilation Jan -July 25.pdf
1st Inaugural Professorial Lecture held on 19th February 2020 (Governance and...
History, Philosophy and sociology of education (1).pptx
Radiologic_Anatomy_of_the_Brachial_plexus [final].pptx
Cell Structure & Organelles in detailed.
Paper A Mock Exam 9_ Attempt review.pdf.
RTP_AR_KS1_Tutor's Guide_English [FOR REPRODUCTION].pdf
UNIT III MENTAL HEALTH NURSING ASSESSMENT
The Lost Whites of Pakistan by Jahanzaib Mughal.pdf

Vicam Ia Working Principle

  • 10. AflaTest • Limit of detection as low as 0.5 ppb (fluorometer) 0.05 ppb (HPLC) • Wide range as high as 320 ppb • AOAC Official Method status • USDA-FGIS Certificate of Conformance
  • 11. FumoniTest • 0.25 ppm (fluorometer) 0.016 ppm (HPLC) limit of detection • Wide range of 0-10 ppm • Excellent linearity: r = 0.998 • Excellent precision: %CV < 11% from 1-10 ppm • Fluorometer method correlates well with HPLC linear regression r = 0.995 • USDA-FGIS Certificate of Conformance
  • 12. ZearalaTest • 0.10 ppm (fluorometer) 0.0025 ppm (HPLC) limit of detection • Wide range of 0-5 ppm • Excellent linearity r = 0.999 • Excellent precision: %CV = 13% over the assay range • Fluorometer method correlates well with HPLC linear regression r = 0.990
  • 13. OchraTest • Limit of detection as low as 1 ppb (fluorometer) 0.25 ppb (HPLC) • Wide range as high as 100 ppb • Excellent linearity with correlation coefficient (r) of 0.997-0.999 for wheat, dried fruit and green coffee • Excellent precision with %CV <10% at 20 ppb • Fluorometer method correlates well with HPLC when analyzed by linear regression
  • 14. DON FQ  Quick - Results in less than 30 minutes (after sample extraction.  Sensitive - Detects levels as low as 0.5 ppm  Wide Range - Measures up to 5 ppm  Convenient - Uses same instrumentation as other VICAM mycotoxin tests  USDA-FGIS Certificate of Conformance
  • 15. DONtest HPLC • limit of detection : 0.1 ppm (HPLC) • Wide range : 0 -10 ppm • Excellent linearity with correlation coefficient (r) of 0.999 : r2 = 0.999 • Excellent precision : with %CV 8.3% • DONtest-HPLC method correlates well with GC- ECD when analyzed by linear regression: r2 = 0.982
  • 16. T-2  Quick - Results in less than 20 minutes (after sample extraction.  Sensitive - Detects levels as low as 0.15 ppm  Wide Range - Measures up to 2.0 ppm  Convenient - Uses same instrumentation as other VICAM mycotoxin tests  Safe - Requires less toxic materials than other methods.
  • 17. T-2 HPLC • limit of detection : 0.005 ppm • Wide range : 0 –1.5 ppm • Excellent linearity with correlation coefficient (r) of 0.999 : r2 = 0.999 • Excellent precision : RSD 3.68%
  • 18. Team Medical & Scientific Sdn. Bhd. 41, Jalan Anggerik Vanilla T31/T, Kota Kemuning, 40460 Shah Alam, Selangor Tel : 603-5122 5108 Fax : 603-5122 1608 Email : info@tms-lab.com Blog : tms-lab.blogspot.com Solely Distribute by :