SlideShare a Scribd company logo
S„A
V„A
S„A
V„A
VM
VR
VH
VHS
How to Order Manifold Base
2 position single
2 position double
2 position single
2 position double
3 position closed center
3 position exhaust center
3 position pressure center 3 position pressure center
3 position exhaust center
3 position closed center
JIS Symbol
5 port 4 port
(B)
2
1
(P)
3
(R)
5
(R)
1
(P)
3
(R)
(A)
4
(B)
2
1
(P)
3
(R)
5
(R)
(A)
4
(B)
2
1
(P)
3
(R)
5
(R)
(A)
4
(B)
2
1
(P)
3
(R)
5
(R)
(A)
4
(B)
2
1
(P)
3
(R)
5
(R)
(A)
4
(B)
2
(A)
4
1
(P)
3
(R)
(B)
2
(A)
4
1
(P)
3
(R)
(B)
2
(A)
4
1
(P)
3
(R)
(B)
2
(A)
4
1
(P)
3
(R)
(B)
2
(A)
4
Caution
3 position closed center
4
3
2 position double
2 position single
2
1
3 position exhaust center
5 3 position pressure center
Type of actuation
SYJA3 201
(Manifold use only)SYJA3 302
SYJA3 402
Without sub-plate
Port size
M5 port with
sub-plate
M5
Nil
M3
Same manifolds as series SYJ3000 are prepared.
SS5YJA3 Fill the same as SS5YJ3
(Example)
SS5YJA3-41-03-M5 1 pc.
∗SYJA3140 1 pc.
∗SYJA3240 1 pc.
∗SYJ3000-21-2A 1 pc.
How to Order
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Without bracket
With bracketF
Nil
Bracket
Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.
········
······························
······························
····················
For Safety Instructions and Solenoid Valve
Precautions, refer to pages 5-11-2 to 6.
4/5 Port Air Operated Valve
Series SYJA3000
Body ported
Base mounted
(4 port)
Base mounted
(5 port)
5-2-19
1
Valve model Type of actuation Port size
1 Ǟ 4/2 (P Ǟ A/B)
Flow characteristics Note 2)
b
0.36 0.12 0.46 0.35 0.120.46
0.33 0.12 0.47 0.31 0.120.47
0.39 0.10
0.59
[0.40]
0.43
[0.33]
0.16
[0.11]
0.36
0.42
[0.33]
0.16
[0.080]
0.46 0.32 0.11
0.58
[0.32]
Cv
C [dm3
/
(s• bar)]
b Cv
C [dm3
/
(s• bar)]
4/2 Ǟ 5/3 (A/B Ǟ EA/EB)
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
M3 x 0.5
Effective
area
mm2
0.9
—M5 x 0.8
—
Weight (g)
22
25
28
48 (22)
51 (25)
54 (28)
22
25
28
Flow Characteristics/Weight
With Bracket
Air operated
valve type
The mounting bracket for the 2 position
double solenoid and 3 position is supplied
unattached.
SYJA3„20-M3-F
Fluid
Specifications
Operating pressure
range
MPa
Ambient and fluid temperature °C
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2
)
2 position single
2 position double
3 position
2 position single
2 position double
3 position
Air
0.15 to 0.7
0.1 to 0.7
0.2 to 0.7
Operating pressure to 0.7
0.1 to 0.7
0.2 to 0.7
–10 to 50 (No freezing. Refer to page 5-11-4.)
Not required
Unrestricted
300/50
M3 x 0.5
M3 x 0.5
M3 x 0.5
Pilot
port size
Pilot Pressure Range (Single pilot)
0.6
0.5
0.4
0.3
0.2
0.1 0.2 0.3 0.4 0.5 0.6
Operating pressure range MPa
PilotpressureMPa
Pilot pressure range
MPa
Body ported
Bodyported
5portbasemounted
(withsub-plate)
4Portbasemounted
(Formanifold)Note1)
Note 2)
Base mounted
2 position
3 position
2 position
3 position
2 position
3 position
Grommet
SYJA3„20-M3
SYJA3„40-M5
SYJA3„30
∗ Refer to memo for contents that have been changed.
Note 1)
Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied
to supply port, because return pressure is introduced from supply port {1(P)} for activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the
main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)
Note 3)
Pilot pressure
range
Note 1) Value when used on a manifold. Refer to page 5-2-19 for
details.
Note 2) [ ]: Denotes normal position.
Note 3) ( ): Without sub-plate.
Note 4) 5 port base mounted without sub-plate: SYJA3„40
Series SYJA3000
5-2-20
2
S„A
V„A
S„A
V„A
VM
VR
VH
VHS
2 position single: SYJA3120-M3(-F)
Dimesions: Body Ported
2 position single: SYJA3140-M5
Dimensions: Base Mounted
2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5
3 position closed center/exhaust center/pressure center
SYJA3 20-M3(-F)
3 position closed center/exhaust center/pressure center
SYJA3 40-M5
A
A B
B
PRR
R P R
A B
PR R
A
AB
B
A
AB
B
A
AB
B
10
(28.4)
(22)
22 4
33
36
28.5
21
13
10
(10)
77
15
15
10
7 7
7
19
49
54.5
21.6
15
13.5
(18.5)
(21)
(18.5)
7.1
(11)(0.5)
10
7 7
(11)(0.5)
1.8
(21)
(18.5)
13.5
7(13.5)
1.5
4
8.2
15
36
(18.5)
41.6
7.1
7
8.2
11
10
36(2)
(16.4)
(35)
11
17.5
22
36
14
41.6
111.5
2.5
17.5
21
10
10
10
9
14 14
15
1010
52.555
1.51.5
1.5
4
8.2
1.5
4
1.5
1.8
22 3
54.5
16
18.9
33
1.5
2.5
11
13
21
28.5
17.5
1.5
(For mounting)
M3 x 0.5
(Pilot port)M3 x 0.5
(Pilot port)
2-M3 x 0.5
(Pilot port)
2-M3 x 0.5
(Pilot port)
2-M3 x 0.5
(Pilot port)
2-M3 x 0.5
(Pilot port)
M5 x 0.8
(Piping port)
M3 x 0.5
(Piping port)
2-ø3.2
(For mounting)
2-ø3.5
(For mounting)
2-ø3.2
(For manifold mounting)
2-ø1.8
(For mounting)
2-ø3.2 equivalent
(For mounting)
2-ø3.2 equivalent
(For mounting)
2-ø3.2
ø1
(Bleed port)
ø1 (Bleed port)
(Bracket)
R2 P R1
14
28
1010
5
R2 P P1
28.5
13
28
1010
910
10
5
5
M5 x 0.8
(Piping port)
M3 x 0.5
(Piping port)
(Piping port)
2-ø1 (Bleed port)
2-ø1 (Bleed port)
M3 x 0.5
2-ø1 (Bleed port)
M5 x 0.8
(Piping port)
2-ø1
(Bleed port)
R2 P R1
3
4
5
3
4
5
Manual override
Manual override
Manual override
Manual override
Manual override
Manual override
5-2-21
Series SYJA30004/5 Port Air Operated Valve
3
(Example)
SS5YJA5-42-03-01 1 set
∗ SYJA5140 1 set
∗ SYJA5240 1 set
∗ SYJ5000-21-1A 1 set
How to Order Manifold Base
3 position closed center
4
3
2 position double
2 position single
2
1
3 position exhaust center
5 3 position pressure center
Type of actuation
One-touch fitting for ø6C6
One-touch fitting for ø4
M5 x 0.8
C4
M5
A, B port size
SYJA5 201
SYJA5 402
Without sub-plate
Port size
1/8
With sub-plate
01
Nil
Rc
G
NPT
NPTF
Thread type
F
N
T
Nil
M5
How to Order
2 position double
3 position exhaust center
2 position single
3 position closed center
3 position pressure center
JIS Symbol
Body ported
2 position double
3 position exhaust center
2 position single
3 position closed center
3 position pressure center
Base mounted
(B)
2
1
(P)
5
(R1)
3
(R2)
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
3
(R)
(A)
4
(B)
2
1
(P)
3
(R)
(A)
4
(B)
2
1
(P)
3
(R)
(A)
4
(B)
2
1
(P)
3
(R)
(A)
4
(B)
2
1
(P)
3
(R)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
(A)
4
Caution
Same manifolds as series SYJ5000 are prepared.
SS5YJA5 Fill the same as SS5YJ5.
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Without bracket
With bracketF
Nil
Bracket
Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.
············
·····························
·····························
···················
For Safety Instructions and Solenoid Valve
Precautions, refer to pages 5-11-2 to 5-11-6.
4/5 Port Air Operated Valve
Series SYJA5000
Body ported
Base mounted
5-2-22
4
S„A
V„A
S„A
V„A
VM
VR
VH
VHS
Valve model Type of actuation Port size
1 Ǟ 4/2 (P Ǟ A/B)
Flow characteristics Note 1)
b Cv
C [dm3
/
(s·bar)] b Cv
C [dm3
/
(s·bar)]
0.41 0.130.47 0.41 0.130.47
0.44 0.130.49 0.40 0.120.44
0.37 0.120.46 0.43
[0.35]
0.13
[0.10]
0.47
[0.39]
0.51
[0.38]
0.14
[0.10]
0.49
[0.39]
0.42 0.120.45
0.39 0.180.69 0.39 0.120.44
0.40 0.190.69 0.40 0.120.43
0.40 0.150.56 0.37
[0.37]
0.10
[0.11]
0.41
[0.41]
0.40
[0.37]
0.15
[0.10]
0.57
[0.41]
0.37 0.100.41
0.36 0.190.70 0.40 0.120.47
0.37 0.190.72 0.34 0.120.44
0.54 0.190.67 0.38
[0.38]
0.11
[0.11]
0.41
[0.41]
0.41
[0.39]
0.23
[0.12]
0.82
[0.44]
0.36 0.110.41
0.21 0.190.79 0.32 0.210.83
0.28 0.180.80 0.34 0.200.86
0.26 0.180.71 0.24
[0.44]
0.26
[0.18]
1.1
[0.60]
0.29
[0.38]
0.24
[0.12]
0.99
[0.47]
0.38 0.180.72
4/2 Ǟ 5/3 (A/B Ǟ EA/EB)
Single
Double
Closed center
Exhaust
center
Pressure
center
Single
Double
Closed center
Exhaust
center
Pressure
center
Single
Double
Closed center
Exhaust
center
Pressure
center
Single
Double
Closed center
Exhaust
center
Pressure
center
M5 x 0.8
1/8
A, B port: C4
(One-touch
fitting for ø4)
P, R port:
M5 x 0.8
A, B port: C6
(One-touch
fitting for ø6)
P, R port:
M5 x 0.8
Weight (g)
45
60
70
52
67
77
52
67
77
Flow Characteristics/Weight
With Bracket
Air operated
valve type
The mounting bracket is supplied unattached.
SYJA5120-M5-F
M5 x 0.8
Pilot
port size
Bodyported
2 position
3 position
2 position
3 position
2 position
3 position
SYJA5„20-M5
SYJA5„20-C4
SYJA5„20-C6
79 (45)
94 (60)
104(70)
M5 x 0.8
Basemounted
(withsub-plate)
2 position
3 position
SYJA5„40-01
0.6
0.5
0.4
0.3
0.1
0.2
0.2 0.3 0.4 0.5 0.6
Operating pressure range MPa
PilotpressureMPa
Pilot pressure range
Pilot Pressure Range (Single pilot)
Fluid
Specifications
Operating pressure
range
MPa
Ambient and fluid temperature °C
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2
)
2 position single
2 position double
3 position
2 position single
2 position double
3 position
Air
0.15 to 0.7
0.1 to 0.7
0.15 to 0.7
(0.4 x P+0.1) to 0.7 P: Operating pressure
0.1 to 0.7
0.15 to 0.7
–10 to 50 (No freezing. Refer to page 5-11-4.)
Not required
Unrestricted
300/50
Pilot pressure range
MPa
Note 2)
Body ported
Base mounted
Note 1) [ ]: Denotes normal position.
Note 2) ( ): Without sub-plate.
Note 3) 5 port base mounted without sub-plate: SYJA5„40
Note 1)
Note 1) In the case of single type, be certain that pressure within operating pressure range be
supplied to supply port, because return pressure is introduced from supply port {1(P)} for
activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the main
valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)
Note 2)
5-2-23
Series SYJA50004/5 Port Air Operated Valve
5
2 position single: SYJA5120-M5(-F)
Dimesions: Body Ported
2 position single: SYJA5140-01२
Dimensions: Base Mounted
2 position double: SYJA5220-M5 2 position double: SYJA5240-01२
3 position closed center/exhaust center/pressure center
SYJA5 20-M5
3 position closed center/exhaust center/pressure center
SYJA5 40-01२
41.5
M5 x 0.8
(Pilot port)
10
5
11
1
15
2-ø2.6 2-ø3.5
2-ø2.6
(For mounting)
(For manifold mounting)
19
23
19.5
21
19
10
(25)
11.5
(37)
(30)
(18)
M5 x 0.8
(Piping port)
(46.5)
24.5
20
3
ø1.8 (Bleed port)
With fiflter (80 mesh)
A B
(Bracket)
(2.3)
3.5 4 11
R1
R2
P
(For mounting)
2-ø2.6
2-M5 x 0.8
(Pilot port)
(For manifold mounting)
44
54
11
21
28
23
10
15
11.5
11
21
32
24
15
15
15 17
47
42
24
1
45.5
17
24
32
17 17
45.5
54
1
1
24
47
42
24
32
17 17
45.5
48 17.5
70.5
43
21.5
8.5
6
6
33.5
46.5
46.5
6
6
8.5
33.5
46.5
33.5
21.5
6
6
8.5
21.5
1
1
24
19
37.5
70.5
5
3
1
1
11
20
23
24.5
20
23
24.5
11.5
15
3
11
5
1
2-ø2.6
(For mounting)
R1
R2
P
B
R1 P
R2
M5 x 0.8
(Piping port)
2-ø1.8 (Bleed port)
2-M5 x 0.8
M5 x 0.8
(Pilot port)
(Piping port)
2-M5 x 0.8
2-M5 x 0.8
(Pilot port)
M5 x 0.8
(Pilot port)
(For manifold mounting)
2-ø2.6
(Piping port)
(For mounting)
2-ø2.6
(For mounting)
2-ø4.3
2-ø1.8 (Bleed port)
2-ø1.8
(Bleed port)
2-ø4.3
(For mounting)
2-ø4.3
1/8
1/8
(Piping port)
1/8
437.5
37.5
37.5
4
2
A
AB
AB
B
A
B
R P
A
AB
B
R P
R P
4
(Piping port)
(Pilot port) (For mounting)
1
ø1.8
(Bleed port)
With fiflter
(80 mesh)
With fiflter
(80 mesh)
With fiflter (80 mesh)
With fiflter (80 mesh)
2-ø1.8
(Bleed port)
With fiflter
(80 mesh)
A
A B
3
4
5
3
4
5
Manual override
Manual override
Manual override
Manual override
Manual override
Manual override
Series SYJA5000
5-2-24
6
S„A
V„A
S„A
V„A
VM
VR
VH
VHS
5-2-25
How to Order Manifold Base
3 position closed center
4
3
2 position double
2 position single
2
1
3 position exhaust center
5 3 position pressure center
Type of actuation
One-touch fitting for ø8C8
One-touch fitting for ø6
1/8
C6
01
A, B port size
SYJA7 201
SYJA7 402
Without sub-plate
Port size
1/8
With sub-plate
01
1/4
With sub-plate
02
Nil
Rc
G
NPT
NPTF
Thread type
F
N
T
Nil
01
How to Order
Same manifolds as series SYJ7000 are prepared.
SS5YJA7 Fill the same as SS5YJ7.
(Example)
SS5YJA7-41-03-01 1 pc.
∗ SYJA7140 1 pc.
∗ SYJA7240 1 pc.
∗ SYJ7000-21-1A 1 pc.
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
2 position double
3 position exhaust center
2 position single
3 position closed center
3 position pressure center
JIS Symbol
Body ported
2 position double
3 position exhaust center
2 position single
3 position closed center
3 position pressure center
Base mounted
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
3
(R2)
5
(R1)
(A)
4
(B)
2
1
(P)
3
(R2)
5
(R1)
(A)
4
(B)
2
1
(P)
3
(R2)
5
(R1)
(A)
4
(B)
2
1
(P)
3
(R2)
5
(R1)
(A)
4
(B)
2
1
(P)
3
(R2)
5
(R1)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
(B)
2
1
(P)
5
(R1)
3
(R2)
(A)
4
Caution
Without bracket
With bracketF
Nil
Bracket
Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along
with the manifold base model no.
·········
····························
····························
·················
For Safety Instructions and Solenoid Valve
Precautions, refer to pages 5-11-2 to 5-11-6.
4/5 Port Air Operated Valve
Series SYJA7000
Body ported
Base mounted
7
With Bracket
Air operated
valve type
As a bracket is designed for a body, be sure
that a bracket is attached when ordering and
operating.
SYJA7120-01-F
Body ported
Base mounted
Fluid
Specifications
Operating pressure
range
MPa
Ambient and fluid temperature °C
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2
)
2 position single
2 position double
3 position
2 position single
2 position double
3 position
Air
0.15 to 0.7
0.1 to 0.7
0.15 to 0.7
(0.4 x P+0.1) to 0.7 P: Operating pressure
0.1 to 0.7
0.15 to 0.7
–10 to 50 (No freezing. Refer to page 5-11-4.)
Not required
Unrestricted
300/50
Pilot pressure range
MPa
Pilot Pressure Range (Single pilot)
0.6
0.5
0.4
0.3
0.1
0.2
0.2 0.3 0.4 0.5 0.6
Pilot pressure range
Operating pressure range MPa
PilotpressureMPa Note 2)
Note 1)
Note 1) In the case of single type, be certain that pressure within operating pressure range be
supplied to supply port, because return pressure is introduced from supply port {1(P)} for
activation.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
The test was performed on the axis and right angle directions of the
main valve, when pilot signal is ON and OFF. (Value in the initial state)
Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz.
Test was performed to axis and right angle directions of the main valve
when pilot signal is ON and OFF. (Value in the initial state)
Series SYJA7000
5-2-26
8
S„A
V„A
S„A
V„A
VM
VR
VH
VHS
Valve model Type of actuation Port size 1 Ǟ 4/2 (P Ǟ A/B)
Flow characteristics Note 2)
b CvC [dm3
/
(s• bar)] b Cv
C [dm3
/
(s• bar)]
4/2 Ǟ 5/3 (A/B Ǟ EA/EB)
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
Single
Double
Closed
center
Exhaust
center
Pressure
center
1/8
1/8 Note 1)
A, B port: C6
(One-touch
fitting for ø6)
P, R port: 1/8
A, B port: C8
(One-touch
fitting for ø8)
P, R port: 1/8
Note 3)
Weight
(g)
90
110
120
101
121
131
101
121
131
170 (90)
190 (110)
200 (120)
170 (90)
190 (110)
200 (120)
Flow Characteristics/Weight
M5 x 0.8
M5 x 0.8
M5 x 0.8
Pilot
port size
Bodyported
2 position
3 position
2 position
2 position
2 position
2 position
3 position
3 position
3 position
3 position
SYJA7„20-01
SYJA7„20-C6
SYJA7„20-C8
SYJA7„40-01
Note 1) P, A, B Port: Rc1/8 is R1, R2 port: Rc (PT) 1/4
Note 2) [ ]: Denotes normal position
Note 3) ( ): Without sub-plate
Note 4) 5 port base mounted without sub-plate: SYJA„40
0.36
0.37
0.50
0.37
[0.50]
0.33
0.27
0.37
0.36
[0.40]
0.39
0.35
0.38
0.57
[0.46]
0.45
0.36
0.48
0.43
[0.54]
0.41
0.46
0.45
0.23
[0.55]
0.58
0.45
0.34
0.78
[0.25]
0.4
0.35
0.27
0.45
[0.22]
0.52
0.42
0.33
0.59
[0.25]
0.57
0.48
0.35
0.78
[0.25]
0.61
0.50
0.35
0.84
[0.25]
0.34
0.35
0.35
[0.52]
0.37
0.32
0.33
0.32
[0.54]
0.30
0.34
0.29
0.35
[0.49]
0.39
0.37
0.46
0.36
[0.57]
0.45
0.35
0.44
0.27
[0.56]
0.47
0.63
0.49
0.73
[0.39]
0.45
0.53
0.49
0.61
[0.38]
0.39
0.61
0.49
0.67
[0.38]
0.42
0.71
0.57
0.86
[0.41]
0.56
0.74
0.60
0.87
[0.43]
0.58
2.4
2.0
3.0
[1.3]
1.8
2.2
1.9
2.5
[1.3]
1.6
2.3
2.0
2.6
[1.3]
1.7
2.8
2.1
3.4
[1.3]
2.1
2.9
2.2
3.7
[1.4]
2.1
1/4 Note 1)
Basemounted(Withsub-plate)
SYJA7„40-02
2.2
1.8
1.2
3.0
[0.83]
1.6
1.4
1.1
1.8
[0.78]
2.0
1.7
1.2
1.9
[0.86]
2.3
1.9
1.2
3.3
[0.85]
2.3
1.9
1.3
3.6
[0.83]
5-2-27
Series SYJA70004/5 Port Air Operated Valve
9
2 position single: SYJA7120-01२(-F)
Dimesions: Body Ported
2 position single: SYJA7140- २
Dimensions: Base Mounted
2 position double: SYJA7220-01२ 2 position double: SYJA7240- २
3 position closed center/exhaust center/pressure center
SYJA7 20-01२
3 position closed center/exhaust center/pressure center
SYJA7 40- २
M5 x 0.8
M5 x 0.8
2-ø3.2
2-ø4.3
2-ø4.5 (For mounting)
(For manifold mounting)
(Piping port)
(Pilot port)
2-M5 x 0.8
2-M5 x 0.8
(For mounting)
60
68.8
63
31.5
2222
63.3
34
R1PR2
B A
8.5
74.6
63.6
31.5
34 8.5
28.3
A B
35
35
(Pilot port)
2-ø4.3
2-M5 x 0.8
(31.9)
27.2
1
63.6
35
27.2
35
38
18
14
211.6
28
25
29
35
27.2
89
32.545.5
17
13
1
1
3
17
13
3
1
25
29
14
18
28
211.6
35
74.6
(34)
(26)
18
18
14
34
27
A
B
R1PR2
A
A
B
65.6
(69.2)
13
21
1.6
29
(44)
(36)
15
11
1
25.5
40
55
54
20
12
11.5
63
2222
20
12
11.5
3
1
2-ø3.2
2-ø3.2
2-ø3.2
2-ø3.2
(For manifold mounting)
(For mounting)
17
(6.8)
1/8
1/8
(P, A, B port)
1/8,1/4
(R1, R2 port)
1/4
1/8,1/4
(P, A, B port)
(R1, R2 port)
1/4
2-ø1.8 (Bleed port)
R1 R2
A
R1 R2P
R1 R2P
B
A B
P
1/8
(Piping port)
18
25.5
40
55
34
27
89
69.5 14
64
31.5
34 8.5
2-ø4.3
(For mounting)
2-M5 x 0.8
(Pilot port)
1
1
34
27
2-ø1.8 (Bleed port)
63
2222
20
12
11.5
1/8,1/4
(P, A, B port)
(R1, R2 port)
1/4
18
25.5
40
55
(For mounting)
(Pilot port)
(Pilot port)(For manifold mounting)
(Piping port)
(Pilot port)
2-ø3.2 (For mounting)
B
R1PR2
A
A
B
B
(For mounting)
3
4
5
3
4
5
ø1.8 (Bleed port)
With fiflter (80 mesh)
Manual override
Manual override
ø1.8
(Bleed port)
With fiflter
(80 mesh)
Manual override
2-ø1.8
(Bleed port)
With fiflter
(80 mesh)
Manual override
With fiflter (80 mesh)
Manual override
With fiflter (80 mesh)
Manual override
2-ø1.8
(Bleed port)
With fiflter
(80 mesh)
(Bracket)
01
02
01
02
01
02
Series SYJA7000
5-2-28
10

More Related Content

PDF
Roboz tech codes.
PDF
Product Catalog
PDF
I p switches-2008
PDF
Iai rcs2 cr_sa7c_specsheet
PDF
Control Valve Selection - Honeywell
PDF
Original N-Channel Mosfet STP9NK70Z 9NK70 700V 7.5A TO-220 New STMicroelectro...
PDF
High Range Pressure Switch KU Series
Roboz tech codes.
Product Catalog
I p switches-2008
Iai rcs2 cr_sa7c_specsheet
Control Valve Selection - Honeywell
Original N-Channel Mosfet STP9NK70Z 9NK70 700V 7.5A TO-220 New STMicroelectro...
High Range Pressure Switch KU Series

What's hot (19)

PDF
Parker valve brochure
PDF
Product guide for industrial gauges from Ametek U.S. Gauge
PDF
Structural insulated panels sips house technical data
PDF
Temporary strainers
PDF
Msv f2 dn15-400
PDF
Industrial Solenoid Valves, Bronze and Stainless Steel
PDF
Toyota 02 5 fg33 forklift service repair manual
PDF
Toyota 02 5 fd45 forklift service repair manual
PDF
Sanitary Ball Valves for Biotech and Pharma Applications
PDF
Bubbler Method Liquid Tank Level Measurement Instruments
PDF
Datasheet 1008s 40_50mm_gauge
PDF
Soldavac tsx70
PDF
Magnetrol Orion Magnetic Liquid Level Indicators
PDF
PDF
Burkert 6013 - 2/2 Solenoid Valve > นิวเมติก.com
PDF
Swagelok Hose Quick Reference Guide
PDF
Catalog bộ nguồn PS5R IDEC mới nhất 2019
PDF
Memcon 1.27mm Mptbwrd series-double-row-thru-hole-right-angle
PDF
Vessel design
Parker valve brochure
Product guide for industrial gauges from Ametek U.S. Gauge
Structural insulated panels sips house technical data
Temporary strainers
Msv f2 dn15-400
Industrial Solenoid Valves, Bronze and Stainless Steel
Toyota 02 5 fg33 forklift service repair manual
Toyota 02 5 fd45 forklift service repair manual
Sanitary Ball Valves for Biotech and Pharma Applications
Bubbler Method Liquid Tank Level Measurement Instruments
Datasheet 1008s 40_50mm_gauge
Soldavac tsx70
Magnetrol Orion Magnetic Liquid Level Indicators
Burkert 6013 - 2/2 Solenoid Valve > นิวเมติก.com
Swagelok Hose Quick Reference Guide
Catalog bộ nguồn PS5R IDEC mới nhất 2019
Memcon 1.27mm Mptbwrd series-double-row-thru-hole-right-angle
Vessel design
Ad

Viewers also liked (16)

PPT
Authority of the believer 1 may 16
PDF
Vqc
PPT
Testosterone
PDF
CWC Women's Ministry Newsletter Feb 2016
PPTX
Iert [recovered]
PDF
Фильтр сверхтонкой очистки Ame
PPTX
It's uncommon
PPTX
Our light afflictions
PDF
The psychologist September 2014
PPTX
It's in the Blood
PDF
Generators softwares
PPTX
The Workmanship of the Believer-- Ephesians 5
PDF
Ar1000
PPT
It’s as simple as ABC
PPTX
Urban Forests in Moscow
PPTX
Marketing plan by amdad and annie
Authority of the believer 1 may 16
Vqc
Testosterone
CWC Women's Ministry Newsletter Feb 2016
Iert [recovered]
Фильтр сверхтонкой очистки Ame
It's uncommon
Our light afflictions
The psychologist September 2014
It's in the Blood
Generators softwares
The Workmanship of the Believer-- Ephesians 5
Ar1000
It’s as simple as ABC
Urban Forests in Moscow
Marketing plan by amdad and annie
Ad

Similar to Syja3000 (20)

PDF
Reguladora de Fluxo - SC3W Series Specifications - ckd corporation
PDF
Vpa4000
PDF
Iai rcp2 cr_sa6c_specsheet
PDF
Iai rcp2 cr_sa5c_specsheet
PDF
3QR・3QB・3QE・3QZ Series -VALVULA 3 VIAS
PDF
Iai rcs2 cr_sa5d_specsheet
PDF
Vta 315
PDF
Iai rca sa4_r_specsheet
PDF
Iai rcp2 sa6_c_specsheet
PDF
Iai erc3 sa5_c_specsheet
PDF
Iai rcs2 sa4_r_1_specsheet
PDF
Iai rcs2 sa5_d_specsheet
PDF
Vpa3145
PDF
Iai rcs2 sa5_r_specsheet
PPT
184608653 02-pa-transaxle
PDF
Iai rcp3 ta4_c_specsheet
PDF
Iai rcp3 ta4_r_specsheet
PDF
Iai rca sa4_c_specsheet
PDF
Iai rcp2 sa7_c_specsheet
PDF
Iai rcp2 srgs4_r_specsheet
Reguladora de Fluxo - SC3W Series Specifications - ckd corporation
Vpa4000
Iai rcp2 cr_sa6c_specsheet
Iai rcp2 cr_sa5c_specsheet
3QR・3QB・3QE・3QZ Series -VALVULA 3 VIAS
Iai rcs2 cr_sa5d_specsheet
Vta 315
Iai rca sa4_r_specsheet
Iai rcp2 sa6_c_specsheet
Iai erc3 sa5_c_specsheet
Iai rcs2 sa4_r_1_specsheet
Iai rcs2 sa5_d_specsheet
Vpa3145
Iai rcs2 sa5_r_specsheet
184608653 02-pa-transaxle
Iai rcp3 ta4_c_specsheet
Iai rcp3 ta4_r_specsheet
Iai rca sa4_c_specsheet
Iai rcp2 sa7_c_specsheet
Iai rcp2 srgs4_r_specsheet

More from kongurpkp (20)

PDF
Evm230
PDF
Evm130
PDF
Vm1000
PDF
Mech obzor
PDF
PDF
Vhk
PDF
Evfa
PDF
Evsa7
PDF
Evfa
PDF
Sya3000
PDF
Evga342
PDF
Vsa3000
PDF
Evpa300
PDF
Syja300
PDF
Din rail
PDF
Sj2000 3000 constr
PDF
Sj2000 3000_overview
PDF
PDF
50 vfe3120 x81r1
PDF
50 vfe3120 x81
Evm230
Evm130
Vm1000
Mech obzor
Vhk
Evfa
Evsa7
Evfa
Sya3000
Evga342
Vsa3000
Evpa300
Syja300
Din rail
Sj2000 3000 constr
Sj2000 3000_overview
50 vfe3120 x81r1
50 vfe3120 x81

Recently uploaded (20)

PDF
1 - Historical Antecedents, Social Consideration.pdf
PDF
Zenith AI: Advanced Artificial Intelligence
PDF
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
PDF
A comparative study of natural language inference in Swahili using monolingua...
PDF
Mushroom cultivation and it's methods.pdf
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
MIND Revenue Release Quarter 2 2025 Press Release
PPTX
Group 1 Presentation -Planning and Decision Making .pptx
PDF
Heart disease approach using modified random forest and particle swarm optimi...
PPTX
TechTalks-8-2019-Service-Management-ITIL-Refresh-ITIL-4-Framework-Supports-Ou...
PDF
Hybrid model detection and classification of lung cancer
PDF
Accuracy of neural networks in brain wave diagnosis of schizophrenia
PPTX
Programs and apps: productivity, graphics, security and other tools
PPTX
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
PDF
Video forgery: An extensive analysis of inter-and intra-frame manipulation al...
PDF
Approach and Philosophy of On baking technology
PDF
Univ-Connecticut-ChatGPT-Presentaion.pdf
PPTX
OMC Textile Division Presentation 2021.pptx
PPTX
1. Introduction to Computer Programming.pptx
PDF
Encapsulation_ Review paper, used for researhc scholars
1 - Historical Antecedents, Social Consideration.pdf
Zenith AI: Advanced Artificial Intelligence
Microsoft Solutions Partner Drive Digital Transformation with D365.pdf
A comparative study of natural language inference in Swahili using monolingua...
Mushroom cultivation and it's methods.pdf
Building Integrated photovoltaic BIPV_UPV.pdf
MIND Revenue Release Quarter 2 2025 Press Release
Group 1 Presentation -Planning and Decision Making .pptx
Heart disease approach using modified random forest and particle swarm optimi...
TechTalks-8-2019-Service-Management-ITIL-Refresh-ITIL-4-Framework-Supports-Ou...
Hybrid model detection and classification of lung cancer
Accuracy of neural networks in brain wave diagnosis of schizophrenia
Programs and apps: productivity, graphics, security and other tools
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
Video forgery: An extensive analysis of inter-and intra-frame manipulation al...
Approach and Philosophy of On baking technology
Univ-Connecticut-ChatGPT-Presentaion.pdf
OMC Textile Division Presentation 2021.pptx
1. Introduction to Computer Programming.pptx
Encapsulation_ Review paper, used for researhc scholars

Syja3000

  • 1. S„A V„A S„A V„A VM VR VH VHS How to Order Manifold Base 2 position single 2 position double 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 3 position pressure center 3 position exhaust center 3 position closed center JIS Symbol 5 port 4 port (B) 2 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) (A) 4 (B) 2 1 (P) 3 (R) 5 (R) (A) 4 (B) 2 1 (P) 3 (R) 5 (R) (A) 4 (B) 2 1 (P) 3 (R) 5 (R) (A) 4 (B) 2 1 (P) 3 (R) 5 (R) (A) 4 (B) 2 (A) 4 1 (P) 3 (R) (B) 2 (A) 4 1 (P) 3 (R) (B) 2 (A) 4 1 (P) 3 (R) (B) 2 (A) 4 1 (P) 3 (R) (B) 2 (A) 4 Caution 3 position closed center 4 3 2 position double 2 position single 2 1 3 position exhaust center 5 3 position pressure center Type of actuation SYJA3 201 (Manifold use only)SYJA3 302 SYJA3 402 Without sub-plate Port size M5 port with sub-plate M5 Nil M3 Same manifolds as series SYJ3000 are prepared. SS5YJA3 Fill the same as SS5YJ3 (Example) SS5YJA3-41-03-M5 1 pc. ∗SYJA3140 1 pc. ∗SYJA3240 1 pc. ∗SYJ3000-21-2A 1 pc. How to Order The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Without bracket With bracketF Nil Bracket Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. ········ ······························ ······························ ···················· For Safety Instructions and Solenoid Valve Precautions, refer to pages 5-11-2 to 6. 4/5 Port Air Operated Valve Series SYJA3000 Body ported Base mounted (4 port) Base mounted (5 port) 5-2-19 1
  • 2. Valve model Type of actuation Port size 1 Ǟ 4/2 (P Ǟ A/B) Flow characteristics Note 2) b 0.36 0.12 0.46 0.35 0.120.46 0.33 0.12 0.47 0.31 0.120.47 0.39 0.10 0.59 [0.40] 0.43 [0.33] 0.16 [0.11] 0.36 0.42 [0.33] 0.16 [0.080] 0.46 0.32 0.11 0.58 [0.32] Cv C [dm3 / (s• bar)] b Cv C [dm3 / (s• bar)] 4/2 Ǟ 5/3 (A/B Ǟ EA/EB) Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center M3 x 0.5 Effective area mm2 0.9 —M5 x 0.8 — Weight (g) 22 25 28 48 (22) 51 (25) 54 (28) 22 25 28 Flow Characteristics/Weight With Bracket Air operated valve type The mounting bracket for the 2 position double solenoid and 3 position is supplied unattached. SYJA3„20-M3-F Fluid Specifications Operating pressure range MPa Ambient and fluid temperature °C Lubrication Mounting orientation Impact/Vibration resistance (m/s2 ) 2 position single 2 position double 3 position 2 position single 2 position double 3 position Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 Operating pressure to 0.7 0.1 to 0.7 0.2 to 0.7 –10 to 50 (No freezing. Refer to page 5-11-4.) Not required Unrestricted 300/50 M3 x 0.5 M3 x 0.5 M3 x 0.5 Pilot port size Pilot Pressure Range (Single pilot) 0.6 0.5 0.4 0.3 0.2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure range MPa PilotpressureMPa Pilot pressure range MPa Body ported Bodyported 5portbasemounted (withsub-plate) 4Portbasemounted (Formanifold)Note1) Note 2) Base mounted 2 position 3 position 2 position 3 position 2 position 3 position Grommet SYJA3„20-M3 SYJA3„40-M5 SYJA3„30 ∗ Refer to memo for contents that have been changed. Note 1) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in the initial state) Note 3) Pilot pressure range Note 1) Value when used on a manifold. Refer to page 5-2-19 for details. Note 2) [ ]: Denotes normal position. Note 3) ( ): Without sub-plate. Note 4) 5 port base mounted without sub-plate: SYJA3„40 Series SYJA3000 5-2-20 2
  • 3. S„A V„A S„A V„A VM VR VH VHS 2 position single: SYJA3120-M3(-F) Dimesions: Body Ported 2 position single: SYJA3140-M5 Dimensions: Base Mounted 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust center/pressure center SYJA3 40-M5 A A B B PRR R P R A B PR R A AB B A AB B A AB B 10 (28.4) (22) 22 4 33 36 28.5 21 13 10 (10) 77 15 15 10 7 7 7 19 49 54.5 21.6 15 13.5 (18.5) (21) (18.5) 7.1 (11)(0.5) 10 7 7 (11)(0.5) 1.8 (21) (18.5) 13.5 7(13.5) 1.5 4 8.2 15 36 (18.5) 41.6 7.1 7 8.2 11 10 36(2) (16.4) (35) 11 17.5 22 36 14 41.6 111.5 2.5 17.5 21 10 10 10 9 14 14 15 1010 52.555 1.51.5 1.5 4 8.2 1.5 4 1.5 1.8 22 3 54.5 16 18.9 33 1.5 2.5 11 13 21 28.5 17.5 1.5 (For mounting) M3 x 0.5 (Pilot port)M3 x 0.5 (Pilot port) 2-M3 x 0.5 (Pilot port) 2-M3 x 0.5 (Pilot port) 2-M3 x 0.5 (Pilot port) 2-M3 x 0.5 (Pilot port) M5 x 0.8 (Piping port) M3 x 0.5 (Piping port) 2-ø3.2 (For mounting) 2-ø3.5 (For mounting) 2-ø3.2 (For manifold mounting) 2-ø1.8 (For mounting) 2-ø3.2 equivalent (For mounting) 2-ø3.2 equivalent (For mounting) 2-ø3.2 ø1 (Bleed port) ø1 (Bleed port) (Bracket) R2 P R1 14 28 1010 5 R2 P P1 28.5 13 28 1010 910 10 5 5 M5 x 0.8 (Piping port) M3 x 0.5 (Piping port) (Piping port) 2-ø1 (Bleed port) 2-ø1 (Bleed port) M3 x 0.5 2-ø1 (Bleed port) M5 x 0.8 (Piping port) 2-ø1 (Bleed port) R2 P R1 3 4 5 3 4 5 Manual override Manual override Manual override Manual override Manual override Manual override 5-2-21 Series SYJA30004/5 Port Air Operated Valve 3
  • 4. (Example) SS5YJA5-42-03-01 1 set ∗ SYJA5140 1 set ∗ SYJA5240 1 set ∗ SYJ5000-21-1A 1 set How to Order Manifold Base 3 position closed center 4 3 2 position double 2 position single 2 1 3 position exhaust center 5 3 position pressure center Type of actuation One-touch fitting for ø6C6 One-touch fitting for ø4 M5 x 0.8 C4 M5 A, B port size SYJA5 201 SYJA5 402 Without sub-plate Port size 1/8 With sub-plate 01 Nil Rc G NPT NPTF Thread type F N T Nil M5 How to Order 2 position double 3 position exhaust center 2 position single 3 position closed center 3 position pressure center JIS Symbol Body ported 2 position double 3 position exhaust center 2 position single 3 position closed center 3 position pressure center Base mounted (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 3 (R) (A) 4 (B) 2 1 (P) 3 (R) (A) 4 (B) 2 1 (P) 3 (R) (A) 4 (B) 2 1 (P) 3 (R) (A) 4 (B) 2 1 (P) 3 (R) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 (A) 4 Caution Same manifolds as series SYJ5000 are prepared. SS5YJA5 Fill the same as SS5YJ5. The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. Without bracket With bracketF Nil Bracket Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. ············ ····························· ····························· ··················· For Safety Instructions and Solenoid Valve Precautions, refer to pages 5-11-2 to 5-11-6. 4/5 Port Air Operated Valve Series SYJA5000 Body ported Base mounted 5-2-22 4
  • 5. S„A V„A S„A V„A VM VR VH VHS Valve model Type of actuation Port size 1 Ǟ 4/2 (P Ǟ A/B) Flow characteristics Note 1) b Cv C [dm3 / (s·bar)] b Cv C [dm3 / (s·bar)] 0.41 0.130.47 0.41 0.130.47 0.44 0.130.49 0.40 0.120.44 0.37 0.120.46 0.43 [0.35] 0.13 [0.10] 0.47 [0.39] 0.51 [0.38] 0.14 [0.10] 0.49 [0.39] 0.42 0.120.45 0.39 0.180.69 0.39 0.120.44 0.40 0.190.69 0.40 0.120.43 0.40 0.150.56 0.37 [0.37] 0.10 [0.11] 0.41 [0.41] 0.40 [0.37] 0.15 [0.10] 0.57 [0.41] 0.37 0.100.41 0.36 0.190.70 0.40 0.120.47 0.37 0.190.72 0.34 0.120.44 0.54 0.190.67 0.38 [0.38] 0.11 [0.11] 0.41 [0.41] 0.41 [0.39] 0.23 [0.12] 0.82 [0.44] 0.36 0.110.41 0.21 0.190.79 0.32 0.210.83 0.28 0.180.80 0.34 0.200.86 0.26 0.180.71 0.24 [0.44] 0.26 [0.18] 1.1 [0.60] 0.29 [0.38] 0.24 [0.12] 0.99 [0.47] 0.38 0.180.72 4/2 Ǟ 5/3 (A/B Ǟ EA/EB) Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center M5 x 0.8 1/8 A, B port: C4 (One-touch fitting for ø4) P, R port: M5 x 0.8 A, B port: C6 (One-touch fitting for ø6) P, R port: M5 x 0.8 Weight (g) 45 60 70 52 67 77 52 67 77 Flow Characteristics/Weight With Bracket Air operated valve type The mounting bracket is supplied unattached. SYJA5120-M5-F M5 x 0.8 Pilot port size Bodyported 2 position 3 position 2 position 3 position 2 position 3 position SYJA5„20-M5 SYJA5„20-C4 SYJA5„20-C6 79 (45) 94 (60) 104(70) M5 x 0.8 Basemounted (withsub-plate) 2 position 3 position SYJA5„40-01 0.6 0.5 0.4 0.3 0.1 0.2 0.2 0.3 0.4 0.5 0.6 Operating pressure range MPa PilotpressureMPa Pilot pressure range Pilot Pressure Range (Single pilot) Fluid Specifications Operating pressure range MPa Ambient and fluid temperature °C Lubrication Mounting orientation Impact/Vibration resistance (m/s2 ) 2 position single 2 position double 3 position 2 position single 2 position double 3 position Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 (0.4 x P+0.1) to 0.7 P: Operating pressure 0.1 to 0.7 0.15 to 0.7 –10 to 50 (No freezing. Refer to page 5-11-4.) Not required Unrestricted 300/50 Pilot pressure range MPa Note 2) Body ported Base mounted Note 1) [ ]: Denotes normal position. Note 2) ( ): Without sub-plate. Note 3) 5 port base mounted without sub-plate: SYJA5„40 Note 1) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in the initial state) Note 2) 5-2-23 Series SYJA50004/5 Port Air Operated Valve 5
  • 6. 2 position single: SYJA5120-M5(-F) Dimesions: Body Ported 2 position single: SYJA5140-01२ Dimensions: Base Mounted 2 position double: SYJA5220-M5 2 position double: SYJA5240-01२ 3 position closed center/exhaust center/pressure center SYJA5 20-M5 3 position closed center/exhaust center/pressure center SYJA5 40-01२ 41.5 M5 x 0.8 (Pilot port) 10 5 11 1 15 2-ø2.6 2-ø3.5 2-ø2.6 (For mounting) (For manifold mounting) 19 23 19.5 21 19 10 (25) 11.5 (37) (30) (18) M5 x 0.8 (Piping port) (46.5) 24.5 20 3 ø1.8 (Bleed port) With fiflter (80 mesh) A B (Bracket) (2.3) 3.5 4 11 R1 R2 P (For mounting) 2-ø2.6 2-M5 x 0.8 (Pilot port) (For manifold mounting) 44 54 11 21 28 23 10 15 11.5 11 21 32 24 15 15 15 17 47 42 24 1 45.5 17 24 32 17 17 45.5 54 1 1 24 47 42 24 32 17 17 45.5 48 17.5 70.5 43 21.5 8.5 6 6 33.5 46.5 46.5 6 6 8.5 33.5 46.5 33.5 21.5 6 6 8.5 21.5 1 1 24 19 37.5 70.5 5 3 1 1 11 20 23 24.5 20 23 24.5 11.5 15 3 11 5 1 2-ø2.6 (For mounting) R1 R2 P B R1 P R2 M5 x 0.8 (Piping port) 2-ø1.8 (Bleed port) 2-M5 x 0.8 M5 x 0.8 (Pilot port) (Piping port) 2-M5 x 0.8 2-M5 x 0.8 (Pilot port) M5 x 0.8 (Pilot port) (For manifold mounting) 2-ø2.6 (Piping port) (For mounting) 2-ø2.6 (For mounting) 2-ø4.3 2-ø1.8 (Bleed port) 2-ø1.8 (Bleed port) 2-ø4.3 (For mounting) 2-ø4.3 1/8 1/8 (Piping port) 1/8 437.5 37.5 37.5 4 2 A AB AB B A B R P A AB B R P R P 4 (Piping port) (Pilot port) (For mounting) 1 ø1.8 (Bleed port) With fiflter (80 mesh) With fiflter (80 mesh) With fiflter (80 mesh) With fiflter (80 mesh) 2-ø1.8 (Bleed port) With fiflter (80 mesh) A A B 3 4 5 3 4 5 Manual override Manual override Manual override Manual override Manual override Manual override Series SYJA5000 5-2-24 6
  • 7. S„A V„A S„A V„A VM VR VH VHS 5-2-25 How to Order Manifold Base 3 position closed center 4 3 2 position double 2 position single 2 1 3 position exhaust center 5 3 position pressure center Type of actuation One-touch fitting for ø8C8 One-touch fitting for ø6 1/8 C6 01 A, B port size SYJA7 201 SYJA7 402 Without sub-plate Port size 1/8 With sub-plate 01 1/4 With sub-plate 02 Nil Rc G NPT NPTF Thread type F N T Nil 01 How to Order Same manifolds as series SYJ7000 are prepared. SS5YJA7 Fill the same as SS5YJ7. (Example) SS5YJA7-41-03-01 1 pc. ∗ SYJA7140 1 pc. ∗ SYJA7240 1 pc. ∗ SYJ7000-21-1A 1 pc. The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. 2 position double 3 position exhaust center 2 position single 3 position closed center 3 position pressure center JIS Symbol Body ported 2 position double 3 position exhaust center 2 position single 3 position closed center 3 position pressure center Base mounted (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 3 (R2) 5 (R1) (A) 4 (B) 2 1 (P) 3 (R2) 5 (R1) (A) 4 (B) 2 1 (P) 3 (R2) 5 (R1) (A) 4 (B) 2 1 (P) 3 (R2) 5 (R1) (A) 4 (B) 2 1 (P) 3 (R2) 5 (R1) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) (A) 4 Caution Without bracket With bracketF Nil Bracket Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. ········· ···························· ···························· ················· For Safety Instructions and Solenoid Valve Precautions, refer to pages 5-11-2 to 5-11-6. 4/5 Port Air Operated Valve Series SYJA7000 Body ported Base mounted 7
  • 8. With Bracket Air operated valve type As a bracket is designed for a body, be sure that a bracket is attached when ordering and operating. SYJA7120-01-F Body ported Base mounted Fluid Specifications Operating pressure range MPa Ambient and fluid temperature °C Lubrication Mounting orientation Impact/Vibration resistance (m/s2 ) 2 position single 2 position double 3 position 2 position single 2 position double 3 position Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 (0.4 x P+0.1) to 0.7 P: Operating pressure 0.1 to 0.7 0.15 to 0.7 –10 to 50 (No freezing. Refer to page 5-11-4.) Not required Unrestricted 300/50 Pilot pressure range MPa Pilot Pressure Range (Single pilot) 0.6 0.5 0.4 0.3 0.1 0.2 0.2 0.3 0.4 0.5 0.6 Pilot pressure range Operating pressure range MPa PilotpressureMPa Note 2) Note 1) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve, when pilot signal is ON and OFF. (Value in the initial state) Vibration resistance: No malfunction occurred in one sweep test between 45 and 2000 Hz. Test was performed to axis and right angle directions of the main valve when pilot signal is ON and OFF. (Value in the initial state) Series SYJA7000 5-2-26 8
  • 9. S„A V„A S„A V„A VM VR VH VHS Valve model Type of actuation Port size 1 Ǟ 4/2 (P Ǟ A/B) Flow characteristics Note 2) b CvC [dm3 / (s• bar)] b Cv C [dm3 / (s• bar)] 4/2 Ǟ 5/3 (A/B Ǟ EA/EB) Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 1/8 1/8 Note 1) A, B port: C6 (One-touch fitting for ø6) P, R port: 1/8 A, B port: C8 (One-touch fitting for ø8) P, R port: 1/8 Note 3) Weight (g) 90 110 120 101 121 131 101 121 131 170 (90) 190 (110) 200 (120) 170 (90) 190 (110) 200 (120) Flow Characteristics/Weight M5 x 0.8 M5 x 0.8 M5 x 0.8 Pilot port size Bodyported 2 position 3 position 2 position 2 position 2 position 2 position 3 position 3 position 3 position 3 position SYJA7„20-01 SYJA7„20-C6 SYJA7„20-C8 SYJA7„40-01 Note 1) P, A, B Port: Rc1/8 is R1, R2 port: Rc (PT) 1/4 Note 2) [ ]: Denotes normal position Note 3) ( ): Without sub-plate Note 4) 5 port base mounted without sub-plate: SYJA„40 0.36 0.37 0.50 0.37 [0.50] 0.33 0.27 0.37 0.36 [0.40] 0.39 0.35 0.38 0.57 [0.46] 0.45 0.36 0.48 0.43 [0.54] 0.41 0.46 0.45 0.23 [0.55] 0.58 0.45 0.34 0.78 [0.25] 0.4 0.35 0.27 0.45 [0.22] 0.52 0.42 0.33 0.59 [0.25] 0.57 0.48 0.35 0.78 [0.25] 0.61 0.50 0.35 0.84 [0.25] 0.34 0.35 0.35 [0.52] 0.37 0.32 0.33 0.32 [0.54] 0.30 0.34 0.29 0.35 [0.49] 0.39 0.37 0.46 0.36 [0.57] 0.45 0.35 0.44 0.27 [0.56] 0.47 0.63 0.49 0.73 [0.39] 0.45 0.53 0.49 0.61 [0.38] 0.39 0.61 0.49 0.67 [0.38] 0.42 0.71 0.57 0.86 [0.41] 0.56 0.74 0.60 0.87 [0.43] 0.58 2.4 2.0 3.0 [1.3] 1.8 2.2 1.9 2.5 [1.3] 1.6 2.3 2.0 2.6 [1.3] 1.7 2.8 2.1 3.4 [1.3] 2.1 2.9 2.2 3.7 [1.4] 2.1 1/4 Note 1) Basemounted(Withsub-plate) SYJA7„40-02 2.2 1.8 1.2 3.0 [0.83] 1.6 1.4 1.1 1.8 [0.78] 2.0 1.7 1.2 1.9 [0.86] 2.3 1.9 1.2 3.3 [0.85] 2.3 1.9 1.3 3.6 [0.83] 5-2-27 Series SYJA70004/5 Port Air Operated Valve 9
  • 10. 2 position single: SYJA7120-01२(-F) Dimesions: Body Ported 2 position single: SYJA7140- २ Dimensions: Base Mounted 2 position double: SYJA7220-01२ 2 position double: SYJA7240- २ 3 position closed center/exhaust center/pressure center SYJA7 20-01२ 3 position closed center/exhaust center/pressure center SYJA7 40- २ M5 x 0.8 M5 x 0.8 2-ø3.2 2-ø4.3 2-ø4.5 (For mounting) (For manifold mounting) (Piping port) (Pilot port) 2-M5 x 0.8 2-M5 x 0.8 (For mounting) 60 68.8 63 31.5 2222 63.3 34 R1PR2 B A 8.5 74.6 63.6 31.5 34 8.5 28.3 A B 35 35 (Pilot port) 2-ø4.3 2-M5 x 0.8 (31.9) 27.2 1 63.6 35 27.2 35 38 18 14 211.6 28 25 29 35 27.2 89 32.545.5 17 13 1 1 3 17 13 3 1 25 29 14 18 28 211.6 35 74.6 (34) (26) 18 18 14 34 27 A B R1PR2 A A B 65.6 (69.2) 13 21 1.6 29 (44) (36) 15 11 1 25.5 40 55 54 20 12 11.5 63 2222 20 12 11.5 3 1 2-ø3.2 2-ø3.2 2-ø3.2 2-ø3.2 (For manifold mounting) (For mounting) 17 (6.8) 1/8 1/8 (P, A, B port) 1/8,1/4 (R1, R2 port) 1/4 1/8,1/4 (P, A, B port) (R1, R2 port) 1/4 2-ø1.8 (Bleed port) R1 R2 A R1 R2P R1 R2P B A B P 1/8 (Piping port) 18 25.5 40 55 34 27 89 69.5 14 64 31.5 34 8.5 2-ø4.3 (For mounting) 2-M5 x 0.8 (Pilot port) 1 1 34 27 2-ø1.8 (Bleed port) 63 2222 20 12 11.5 1/8,1/4 (P, A, B port) (R1, R2 port) 1/4 18 25.5 40 55 (For mounting) (Pilot port) (Pilot port)(For manifold mounting) (Piping port) (Pilot port) 2-ø3.2 (For mounting) B R1PR2 A A B B (For mounting) 3 4 5 3 4 5 ø1.8 (Bleed port) With fiflter (80 mesh) Manual override Manual override ø1.8 (Bleed port) With fiflter (80 mesh) Manual override 2-ø1.8 (Bleed port) With fiflter (80 mesh) Manual override With fiflter (80 mesh) Manual override With fiflter (80 mesh) Manual override 2-ø1.8 (Bleed port) With fiflter (80 mesh) (Bracket) 01 02 01 02 01 02 Series SYJA7000 5-2-28 10